Smart solutions for
Data Center Monitoring
Continuous temperature, humidity and water leak monitoring that protects critical IT infrastructure and prevents costly downtime before it happens.
Data center environmental monitoring
Data center monitoring solutions that protect infrastructure before problems escalate
Data centers and server rooms operate within tight environmental parameters - and when those parameters are breached, the consequences are immediate and expensive. A temperature spike that goes undetected for an hour can cause hardware failure. A slow water leak under a raised floor can destroy an entire rack before anyone notices. A fire alarm that activates in an unmanned facility with no monitored system in place means nobody responds until it is too late. Our data center monitoring sensors track temperature, humidity, water presence and fire alarm status continuously - alerting your team the moment anything deviates from safe operating conditions, day or night, across every facility you manage.
Use Cases
Data Center Temperature Monitoring
ASHRAE recommends inlet temperatures between 18-27°C and relative humidity between 20-80% RH as the safe operating envelope for IT equipment - and data center temperature and humidity standards exist precisely because deviations cause hardware failure, condensation damage and reduced equipment lifespan. Most facilities rely on spot checks or basic alarms that only trigger after conditions have already become dangerous. Our temperature and humidity monitor provides continuous, real-time readings across every zone, alerting your team the moment conditions approach critical thresholds - before equipment is at risk.
Water Leak Detection Under Raised Floors
Water leaks under raised floors are one of the most destructive risks in any data center or server room - and one of the hardest to detect early. By the time water reaches visible surfaces, significant damage has often already occurred to cabling, power distribution and server hardware. A water leak monitoring system placed under raised floors and near cooling units gives your team an instant alert the moment water is detected - turning a potentially catastrophic event into a manageable maintenance task.
Fire Alarm Monitoring for Unmanned Facilities
Data centers and server rooms are frequently unmanned - particularly overnight and at weekends. When a fire alarm activates with no one on site and no monitored fire alarm system in place, the response time can be catastrophic. Our Fire Sense connects to your existing fire alarm panels and delivers instant push notifications to your team the moment an alarm activates, ensuring someone is always notified immediately - regardless of the time or whether anyone is physically present.
Air Quality and CO Monitoring
Diesel generator exhaust, cooling system refrigerant leaks and poor ventilation in server rooms can create dangerous CO and TVOC build-up that poses serious risks to both equipment and the engineers who work in these environments. Our Pro sensor monitors CO, TVOC, CO2 and particulates continuously, alerting your team to air quality issues before they become a health and safety incident or cause equipment damage from corrosive airborne contaminants.
Multi-Site Data Center Monitoring Systems
Managing environmental compliance across multiple data centers and server rooms without centralised visibility means relying on local alerts that may not reach the right person at the right time. Our platform consolidates every sensor across every facility into one dashboard - temperature, humidity, water leak status, fire alarm activity - giving infrastructure managers and operations teams full visibility, instant alerts and exportable reports from a single screen.
Why Clear The Air
Six reasons data center and IT infrastructure teams choose us.
Protect uptime and equipment
Early deviation alerts mean you intervene before hardware is at risk. The cost of one prevented outage far exceeds the cost of the entire monitoring system.
No load on your network
NB-IoT connectivity means data center monitoring sensors transmit data without placing any additional load on your existing IT infrastructure - completely independent of your network.
Instant alerts, any time
Temperature spike at 3am. Water detected under the raised floor. Fire alarm activation. Your team knows the moment it happens - whether the facility is staffed or not.
One dashboard, every facility
Whether you manage one server room or a network of data centers, every sensor across every facility in one platform. Full visibility without site visits.
Deploy in minutes, not days
No engineers, no cabling, no network configuration. Place the sensor, power it on, it connects and starts transmitting - data center monitoring live in minutes.
Audit and compliance ready
Continuous timestamped environmental data across every facility - exportable reports ready for ISO 27001, Uptime Institute and client audits without manual data compilation.
Recommended Products
The sensors most commonly deployed in data centers, server rooms and critical IT environments.

CTA-PRO
Pro - Indoor Air Quality Monitor
For server rooms and data halls where air quality alongside temperature and humidity needs monitoring. Tracks CO, TVOC, CO2, PM2.5, temperature and humidity - a complete data center monitoring solution in one device.

CTA-TH
Lite - Temperature and Humidity Sensor
The most cost-effective data center monitoring sensor for large-scale deployments where temperature and humidity are the primary concern. Continuous logging against ASHRAE standards, instant deviation alerts, up to 3 years battery life.

CTA-FS
Fire Sense - Fire Alarm Monitor
Unmanned data centers and server rooms need instant fire alarm notification regardless of whether staff are present. Fire Sense connects to your existing panels and puts your team on alert the moment an alarm activates - around the clock.

CTA-WS
Water Sense - Water Leak Detector
Deploy under raised floors, near cooling units and around UPS systems where water leaks cause the most damage. Detects water presence instantly and alerts your team before a slow leak becomes a catastrophic equipment failure.