{"product_id":"clear-the-air-enviro-station-outdoor-air-quality-monitor","title":"Enviro Station - Outdoor Air Quality Monitor","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eOutdoor Air Quality Monitor and Environmental Monitoring Station\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe Clear The Air Enviro Station (CTA-ES) is a professional outdoor air quality monitor and multi-sensor environmental monitoring station designed for smart cities, construction sites, industrial facilities and environmental compliance applications. Measuring ten environmental parameters simultaneously, it delivers comprehensive real-time data on air pollution, weather conditions and environmental changes from a single ruggedised outdoor unit.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhat It Monitors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003ePM2.5 and PM10. Fine and coarse particulate matter from 0 to 1,000 μg\/m³. Critical for construction site COSHH compliance, urban air quality monitoring and public health reporting.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eNO₂ (Nitrogen Dioxide). From 0 to 20ppm. A key indicator of traffic pollution and industrial emissions, monitored for environmental compliance and smart city applications.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSO₂ (Sulphur Dioxide). From 0 to 100ppm. Industrial emissions monitoring for environmental permit compliance.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eCO (Carbon Monoxide). From 0 to 1,000ppm. Outdoor carbon monoxide monitoring for construction sites, industrial facilities and urban environments.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eO₃ (Ozone). From 0 to 20ppm. Ground-level ozone monitoring for environmental reporting and public health applications.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eNoise. From 30 to 130dB for environmental noise monitoring in construction, industrial and urban settings.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWind Speed. From 0 to 75 m\/s for weather analysis and environmental impact assessment.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eAtmospheric Pressure. From 10 to 1,300 hPa.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eHumidity. From 0 to 100%.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eRainfall. From 0 to 5mm per minute.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWho Needs It\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eConstruction Sites. HSE and local authority requirements for dust and air quality monitoring on construction sites are increasingly stringent. It monitors PM2.5, PM10, NO₂ and CO in real time, providing automatic alerts when levels breach compliance thresholds and exportable reports for regulatory submission.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSmart Cities and Local Authorities. Urban air quality monitoring networks require reliable, low-maintenance outdoor sensors capable of measuring multiple pollutants simultaneously. It provides the data local authorities need to understand pollution sources, identify hotspots and demonstrate compliance with UK and EU air quality standards.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eIndustrial Facilities and Environmental Compliance. Factories, processing plants and industrial sites operating under environmental permits require continuous emissions monitoring. The unit monitors NO₂, SO₂, CO and O₃ simultaneously with data transmitted directly to the Clear The Air platform for real-time compliance reporting.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eEnvironmental Research and Monitoring Networks. Universities, research institutions and environmental agencies use it to build outdoor monitoring networks that track long-term environmental trends and support evidence-based policy decisions.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eWhy Choose the CTA-ES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eIndustrial-grade sensors across ten parameters. Most outdoor monitoring solutions require multiple separate units to cover particulates, gases, noise and weather. The CTA-ES replaces all of them — PM2.5, PM10, NO₂, SO₂, CO, O₃, noise, wind speed, atmospheric pressure and rainfall monitored simultaneously from a single station with industrial-grade accuracy. Fewer units, lower installation costs, one platform.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eBuilt for permanent outdoor deployment. IP65 rated enclosure operating from -50°C to +80°C — designed for years of continuous operation in all weather conditions without maintenance.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eFlexible power options. Runs on 9-30 VDC, optional solar power or mains supply — suitable for remote sites with no mains infrastructure.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e4G and 2G connectivity. Reliable data transmission from any location with mobile signal coverage.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eCompact and robust. At 140 x 140 x 350mm with a 3.5m cable, it installs on standard mounting poles and structures without specialist equipment.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eFull platform access via the Clear The Air web platform and mobile app. Real-time data, custom threshold alerts, historical trending and exportable compliance reports for HSE, Environment Agency, local authority and EU regulatory submissions.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eRS485 and RS232 interfaces for integration with existing environmental monitoring systems, SCADA platforms and third party software.\u003c\/p\u003e","brand":"CleanAirMonitoring","offers":[{"title":"Default Title","offer_id":57627770716543,"sku":"CTA-ES","price":3999.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/7863\/9743\/files\/clear-the-air-enviro-station.png?v=1779894470","url":"https:\/\/www.airqualitymonitors.net\/products\/clear-the-air-enviro-station-outdoor-air-quality-monitor","provider":"AirQualityMonitors","version":"1.0","type":"link"}